Overview
Furnace size: 500mm*500mm*500mm
Power: 380V/50Hz 21KW
Heating temperature: Maximum temperature 1200℃, Continuous working temperature ≦110℃
Heating speed: Recommended ≤10℃/min, Fastest heating speed 20℃/min
Temperature control method: Artificial intelligence adjustment technology, with PID adjustment, self-tuning function, 30-stage temperature rise and fall program
Temperature control accuracy: Temperature control accuracy ±1℃
Control mode: Fully automatic PLC control
Furnace structure: Double-layer shell structure, equipped with air cooling and water cooling system, which can quickly cool down the furnace surface
Gas source: nitrogen, argon
Integrated vacuum pump
Machine size: 1260(W)mm×960(D)mm×1680(H)mm
Weight: 500KG
Function: Power off when door is opened, over-temperature alarm, automatic air intake and exhaust, leakage protection
Installation conditions:
1. Gas source requirements: argon/nitrogen, gas pipe: φ10PU pipe;
2. Power supply requirements: one 380V/40A circuit breaker, safe grounding;
3. The installation environment should be well ventilated.
Remark: Applicable to iSLM160 iSLM280 iSLM350 iSLM420, not for dental use